Florida Department of Environmental Protection Bob Martinez Center 2600 Blair Stone Road Tallahassee, Florida 32399-2400 |
Storage Tanks & Contamination Monitoring Information |
|||||||||
| Journal Report | |||||||||||
| Report Run Date: 04/25/2021 Last Data Refresh: 04/24/2021 Report Generated from DOPPLER | |||||||||||
| Facility ID: | 8842053 | ||||||||||
| Facility Name: | DWAINS GROCERY #1 | ||||||||||
| 11/20/2008 | Enforcement Referral Activity | Bristol, Susan M. | |||||||||
| Activity Result: | Accepted | Activity Status: | Closed | ||||||||
| Activity Closed Date: | 11/20/2008 | ||||||||||
| Events: | |||||||||||
| Event Type: | Activity/Document was accepted on this date | Date: | 11/20/2008 | ||||||||
| Comment: | The Northwest District Storage Tank Section accepts the enforcement referral from the Northwest District Storage Tank Section for the cleanup of the September 16, 2004 discovery of contamination. | ||||||||||
| Events: | |||||||||||
| Event Type: | Activity/Document was acknowledged on this date | Date: | 11/20/2008 | ||||||||
| Comment: | The Northwest District Storage Tank Section acknowledges the submittal of the enforcement referral by the Northwest District Storage Tank Section for the cleanup of the September 16, 2004 discovery of contamination. | ||||||||||
| Events: | |||||||||||
| Event Type: | Activity has been submitted for approval | Date: | 11/20/2008 | ||||||||
| Comment: | The Northwest District Storage Tank Section is submitting this enforcement referral to the Northwest District Storage Tank Section for the cleanup of the September 16, 2004 discovery of contamination. | ||||||||||
| Comments: | |||||||||||
| Comment Date: | 11/21/2008 | User: | BRISTOL_S | ||||||||
| Description: | The Northwest District Storage Tank Section accepts the enforcement referral from the Northwest District Storage Tank Section for the overdue SAR for the May 10, 2002 discovery of contamination. | ||||||||||
| 11/20/2008 | Enforcement Tracking Activity | Bristol, Susan M. | |||||||||
| Activity Status: | Open | ||||||||||
| Comments: | |||||||||||
| Comment Date: | 11/21/2008 | User: | BRISTOL_S | ||||||||
| Description: | The Northwest District Storage Tank Section has opened this enforcement referral activity for the overdue SAR for the May 10, 2002 discovery of contamination. | ||||||||||
| 08/25/2004 | Legacy Activity | Brooks, Addie | |||||||||
| Activity Name: | TANK CLOSURE INSPECTION | Activity Status: | Closed | ||||||||
| 04/13/2004 | Violation Closed | Brooks, Addie | |||||||||
| Significance: | SNC-B | Status: | Closed | ||||||||
| Rule: | 800(3)(b)1 | ||||||||||
| Comments: | |||||||||||
| Comment Date: | 02/14/2019 | User: | FRENCH_EC_1 | ||||||||
| Description: | Performed inspect on: 2/14/19 Placard: Provided FR: State FAC CFR: State FAC Monthlys: Provided Annual Operability: Provided for basin alarm. FAC is going to have spill bucket and site gauge tested. Overfill: Site gauge Anti-siphon: NA Tank1: OK Containment Area: NA Spill Buckets: OK-Minor rust Dispensers/Hoses: OK Leak Detection: monthly visual, electronic interstice monitoring (basin alarm), DW. | ||||||||||
| 04/13/2004 | Legacy Activity | Brooks, Addie | |||||||||
| Activity Name: | TANK ANNUAL COMPLIANCE INSPECTION | Activity Status: | Closed | ||||||||
| 04/13/2004 | Violation Closed | Brooks, Addie | |||||||||
| Significance: | Minor | Status: | Closed | ||||||||
| Rule: | 800(4)(a)&(b) | ||||||||||
| Comments: | |||||||||||
| Comment Date: | 02/14/2019 | User: | FRENCH_EC_1 | ||||||||
| Description: | Performed inspect on: 2/14/19 Placard: Provided FR: Provided CFR: Provided Monthlys: Provided Annual Operability: Provided for basin alarm. Provide for the spill bucket and site gauge. Overfill: site gauge Anti-siphon: NA Tank1: OK Containment Area: NA Spill Buckets: OK Dispensers/Hoses: OK Leak Detection: monthly visual, electronic interstice monitoring (basin alarm), DW. | ||||||||||
| 04/08/2003 | Violation Closed | Brooks, Addie | |||||||||
| Significance: | SNC-B | Status: | Closed | ||||||||
| Rule: | 800(3)(b)1 | ||||||||||
| Comments: | |||||||||||
| Comment Date: | 03/01/2017 | User: | ESAU_KL_1 | ||||||||
| Description: | From: Kim Esau Sent: Wednesday, March 01, 2017 3:07 PM To: 'smurto@fpua.com' Cc: Martha Rutherfoord Subject: DEP ID #9103413 TANKS NON COMPLIANCE LETTER - Ft Pierce Utilities Authority-WTP, 715 S 25th St, FTP Attachments: 9103413.NCL-FINAL.STLUCIE.pdf Steve Murto – Ft. Pierce Utilities Authority: Attached, please find correspondence and inspection report from Palm Beach County Department of Environmental Resources Management’s Petroleum Storage Tank Compliance Program for the subject site. Please respond to this email for confirmation of receipt. If you have any questions, please contact Patrick Wille at (561) 233-2505 or by email at pwille@pbcgov.org. | ||||||||||
| 04/08/2003 | Legacy Activity | Brock, Melissa | |||||||||
| Activity Name: | TANK ANNUAL COMPLIANCE INSPECTION | Activity Status: | Closed | ||||||||
| 04/08/2003 | Violation Closed | Brooks, Addie | |||||||||
| Significance: | Minor | Status: | Closed | ||||||||
| Rule: | 800(4)(a)&(b) | ||||||||||
| Comments: | |||||||||||
| Comment Date: | 03/01/2017 | User: | ESAU_KL_1 | ||||||||
| Description: | From: Kim Esau Sent: Wednesday, March 01, 2017 3:15 PM To: 'smurto@fpua.com' Cc: Martha Rutherfoord Subject: DEP ID #8943872 TANKS NON COMPLIANCE LETTER - Ft Pierce Utility Authority - Lawnwood Gen, 1800 S 23rd St, FTP Attachments: 8943872.ncl-FIANL.STLUCIE.pdf Steve Murto – Ft. Pierce Utilities Authority: Attached, please find correspondence and inspection report from Palm Beach County Department of Environmental Resources Management’s Petroleum Storage Tank Compliance Program for the subject site. Please respond to this email for confirmation of receipt. If you have any questions, please contact Patrick Wille at (561) 233-2505 or by email at pwille@pbcgov.org. | ||||||||||
| 05/14/2002 | Violation Closed | Brooks, Addie | |||||||||
| Significance: | SNC-B | Status: | Closed | ||||||||
| Rule: | 800(3)(b)1 | ||||||||||
| Comments: | |||||||||||
| Comment Date: | 04/27/2015 | User: | PERRY_JF_2 | ||||||||
| Description: | All the testing has been conducted and is now current. Tanks passed breach of integrity testing. Dispenser entry boots have been repaired. The repairs have been conducted without concrete removal, etc. No closure assessment conducted. Dispenser passed hydro test after work has been completed. | ||||||||||
| 05/14/2002 | Legacy Activity | Brock, Melissa | |||||||||
| Activity Name: | TANK ANNUAL COMPLIANCE INSPECTION | Activity Status: | Closed | ||||||||
| 05/14/2002 | Violation Closed | Brooks, Addie | |||||||||
| Significance: | Minor | Status: | Closed | ||||||||
| Rule: | 800(4)(a)&(b) | ||||||||||
| Comments: | |||||||||||
| Comment Date: | 04/28/2015 | User: | MORRISON_CY_1 | ||||||||
| Description: | Onsite for annual compliance inspection. Physical inspection performed on 4/27/15. Site photo/map verified and are attached to the facility information page in FIRST. DEP registration placard observed and the facility/owner/tank registration information verified. Current insurance for tanks observed - Chartis Specialty. RELEASE DETECTION: Tanks interstitial: Krueger Sentry gauge checked weekly. AST exterior visually inspected monthly. PHYSICAL INSPECTION OBSERVATIONS: TANKS: Inspected 1 AST system. Double wall Convault tank. Exterior well maintained. Compartmentalized tank. SPILL BUCKETS: Inspected 2 spill buckets. Clean/dry with no obvious integrity problems. Fillports color coded according to proper API standards. Krueger Sentry gauges for overfill protection checked. OK. Krueger Sentry gauge for leak detection checked. OK. Anti-siphon valves present. Note: Inspection reports are sent to facility via e-mail. | ||||||||||
| 05/24/2001 | Violation Closed | Brooks, Addie | |||||||||
| Significance: | Minor | Status: | Closed | ||||||||
| Rule: | 800(4)(a)&(b) | ||||||||||
| Comments: | |||||||||||
| Comment Date: | 06/06/2013 | User: | COLSON_NJ_1 | ||||||||
| Description: | Inspection Date: 06/04/2013 By: Nathan Colson Parties Present: John Whitney Compliance Inspection Covers: 1000 gal. Emergency Generator Diesel, double walled AST. Placard: on display Dates: 2012 to 2013 Release Detection Response Level: on site Certificate of Financial Responsibility: Filled out during inspection. Colony 02/23/2013 to 02/23/2014 *Be sure to fill out a new CoFR every year when the insurance policy renews. Registration Codes Accurate: The tank is registered as underground. Need to change the code to an aboveground tank. Sent a blank registration with the inspection report to be signed & returned. --------------------------------------------------------------------------------------------------- Release Detection Method: Monthly visuals of the tank, spill bucket, piping, and tank interstice (alarm status). Dates Checked: 04/30/2012 to 05/28/2013 Results: Recorded every month & no more than 35 days apart. --------------------------------------------------------------------------------------------------- Tests: Type: Date Tested: Results: Next Date Due: Annual Operability 06/04/2013 Pass 06/04/2014 (Rupture Basin Alarm System) Tested By: John Whitney The annual test of the rupture basin sensor was due by 04/13/2013, but not performed until this inspection. *Be sure to perform the operability test within 12 months of the last test date. --------------------------------------------------------------------------------------------------- Fills Marked per API 1637: yes Overfill Prevention: Krueger level gauge Spill Bucket Condition: ( 1 total) Clean & dry. Tank Condition: Good. No cracks, rust, or leaks observed. Piping: Minimal aboveground, suction piping associated with the generator connection. Equipped with Anti-Gravity Valve: N/A Tank Interstice: Dry according to the alarm status at the time of inspection. Blue light was not lit. Lit once the sensor was flipped for the annual test. Light went off when the sensor was repositioned in the rupture basin. Liquid Sensors: ( 1 total) Located in the rupture basin of the tank. Sensors monitored by: Baldor generator panel. (A blue light shines if the sensor is in alarm.) | ||||||||||
| 05/24/2001 | Violation Closed | Brooks, Addie | |||||||||
| Significance: | SNC-B | Status: | Closed | ||||||||
| Rule: | 800(3)(b)1 | ||||||||||
| Comments: | |||||||||||
| Comment Date: | 06/06/2013 | User: | STEWART_TJ_1 | ||||||||
| Description: | Facility called for a re-inspection. Found that repairs had been made at the spill containment cabinet and the dispenser, the interstitial monitor piping had been identified and is being checked monthly, current inspection records are provided along with a really well done RDRL, and storm water has been removed and the UDL structure cleaned out. The facility has come back into compliance. Good job! | ||||||||||
| 05/24/2001 | Legacy Activity | Brock, Melissa | |||||||||
| Activity Name: | TANK ANNUAL COMPLIANCE INSPECTION | Activity Status: | Closed | ||||||||